Peptide Calculator

Concentration and exactly where to draw on a U-100 insulin syringe.

Free · no account needed
1

Compound (blank = no name)

2

Desired Amount Per Dose

mg
units (U-100)
3

Vial Strength (Total mg of Your Vial)

mg
4

Reconstitution Solution Added

mL
5

Titration Schedule (off = no titration)

Results
Draw to
—units
Enter amount, vial and Reconstitution Solution
ConcentrationConc.
—mg/mL
Your dose
—mg
Doses / vial
—
U-100 Syringe · 1 mL
PeptideWhizpeptidewhiz.app · research use only
Vial ToolsReconstitution Solution amount, syringe picker, first vial walkthrough, vial timeline and COA check.
Research use only (RUO). Results are math on the values you enter only, not a recommendation or prescription for human use. Not medical advice. Always verify your own measurements. Full disclaimer

How peptide reconstitution math works

Most research peptides ship as a dry powder in a sealed vial. Before any amount can be measured, the powder is mixed with a liquid such as bacteriostatic water. That step is called reconstitution. Once the powder dissolves, every millilitre of liquid carries an equal share of what was in the vial, so the whole job comes down to two simple formulas. This calculator does that arithmetic for you and draws the result on a syringe, but it helps to understand what is happening so you can check any number yourself.

Step 1: concentration = amount in vial ÷ water added

If a vial holds 10 mg and you add 2 mL, the liquid holds 10 ÷ 2 = 5 mg in every mL. Because 1 mg is 1,000 mcg, that is also 5,000 mcg/mL. Keep units consistent: if your amount is in mcg, convert the vial to mcg first, or convert your amount to mg. Mixing mg and mcg in one formula is the most common source of answers that are off by a factor of 1,000.

Step 2: volume = amount wanted ÷ concentration

To find how much liquid holds a given amount, divide that amount by the concentration. The result is in mL. On a U-100 insulin syringe, 1 mL is 100 units, so multiply mL by 100 to get the mark to read on the barrel: units = mL × 100.

Worked example example math, not a dose

These numbers are picked only to show the arithmetic. They are not a suggestion for anyone.

  • Vial: 10 mg. Water added: 2 mL.
  • Concentration: 10 mg ÷ 2 mL = 5 mg/mL (5,000 mcg/mL).
  • Amount to measure for the example: 0.5 mg (500 mcg).
  • Volume: 0.5 mg ÷ 5 mg/mL = 0.1 mL.
  • Syringe mark: 0.1 mL × 100 = 10 units on a U-100 syringe.
  • Measures per vial: 10 mg ÷ 0.5 mg = 20.

Reverse math: from units back to an amount

Sometimes you know the mark on the syringe and want to know what it holds. Divide the units by 100 to get mL, then multiply by the concentration. In the example above, 20 units is 0.20 mL, and 0.20 mL × 5 mg/mL = 1 mg. Type a units number into the "units on syringe" box in step 2 and the calculator runs this reverse math for you.

mg and mcg converter

1 mg = 1,000 mcg, and 1 mcg = 0.001 mg. So 0.1 mg = 100 mcg, 0.25 mg = 250 mcg, 2 mg = 2,000 mcg. The mg / mcg switch in the calculator converts for you. IU is different: it measures activity, not weight, so the tool uses the IU count on your own vial label and never assumes 1 IU equals any fixed weight.

Syringe sizes explained

U-100 insulin syringes come in common barrel sizes of 0.3 mL (30 units), 0.5 mL (50 units) and 1 mL (100 units). The unit scale is the same on all of them, 1 unit = 0.01 mL, but smaller barrels spread the marks further apart, which makes small volumes easier to read. Some 0.3 mL barrels also show half-unit marks. If a result is more than 100 units it will not fit in one 1 mL draw, and the calculator shows a warning. Syringes labelled U-40 or in plain mL use a different scale, so the unit numbers here apply only to U-100.

Common mistakes

  • Mixing mg and mcg in the same formula (answers off by 1,000×).
  • Reading a U-100 result on a U-40 or plain-mL syringe.
  • Forgetting that more water lowers concentration but does not change the total in the vial.
  • Using the planned water volume instead of the amount actually added.
  • Treating IU as if it were a weight.

Everything above is general math. PeptideWhiz does not suggest amounts, schedules or uses, and nothing here is medical advice. For research use only.

Peptide calculator FAQ

How do I calculate peptide concentration after adding water?

Divide the amount in the vial by the volume of water you added. A 10 mg vial mixed with 2 mL gives 10 ÷ 2 = 5 mg/mL, which is the same as 5,000 mcg/mL.

How many units are in 1 mL on a U-100 syringe?

A U-100 insulin syringe is marked so that 100 units equal 1 mL. Each unit is 0.01 mL, so 0.25 mL reads as 25 units.

How do I convert mg to mcg?

Multiply milligrams by 1,000. 1 mg = 1,000 mcg, so 0.25 mg = 250 mcg. To go back, divide mcg by 1,000.

Can I convert units on the syringe back to an amount?

Yes. Divide the units by 100 to get mL, then multiply by the concentration. 20 units = 0.20 mL; at 5 mg/mL that holds 1 mg. The calculator does this when you type units into the units box.

Does adding more water change how much is in the vial?

No. The total in the vial stays the same. More water lowers the concentration, so the same amount takes up more volume and more units on the syringe.

Why is IU treated differently from mg?

IU measures biological activity, not weight, so there is no universal IU-to-mg rule. The calculator uses the IU count printed on your own vial label instead of guessing.

Does PeptideWhiz suggest doses?

No. PeptideWhiz never suggests or recommends an amount. Every number comes from you, and the tool only does the arithmetic. It is not medical advice.

Do I need an account to use the calculator?

No. The calculator is free and works without an account. An account only lets you save results to your stack and tracker.

Sources

  • NIST, Metric (SI) prefixes: milli and micro (nist.gov)
  • NIST Special Publication 811, Guide for the Use of the International System of Units (nist.gov)
  • ISO 8537, Sterile single-use syringes for insulin (iso.org)
  • MedlinePlus, Giving an insulin injection: reading syringe units (medlineplus.gov)

Editorial review by Erik Gregory, Founder · Last updated Oct 31, 2026 · Editorial policy

Dosing Protocols Research